blueMatic EAV
Installation, Operating and
Maintenance Instructions
• Connect the terminals 2 through 5 of the wireless receiver as described in the
table below.
No. Name
P1 button
green LED
red LED
Buzzer
Relay
Jumper 12 V / 24 V
Figure 3.5.1-1: Terminal assignment of the wireless receiver
No. Terminals wireless receiver
1
"Break contact (NC)", is not required
2
"Contact (C)", connect with a green wire from the cable transition
3
"Make contact (NO)", connect to terminal 4 of the wireless receiver
(+ 12 V DC)
4
"12 V DC or 24 V DC", Power supply, e.g. from the Winkhaus power
supply (connect with white wire from the cable tran terminal 2
from the wireless receiver)
5
"0 V DC", Power supply, e.g. from the Winkhaus power supply (connect
with brown wire from the cable transition)
6
"Auxiliary antenna / ANT" (not required)
7
"Auxiliary antenna / GND" (not required)