5044744
52
3
EN
Aug. Winkhaus GmbH & Co. KG
∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMatic EAV
Installation, Operating and
Maintenance Instructions
Figure 3.5.2-2: Installation of the circuit board of the receiver
JP1 = ON
K4 ON / OFF
No.
Terminals circuit board of the receiver
8, 9
NO relay K4 - non-operated contact is open, it closes by activating
per remote control
9, 10
NC relay K4 - non-operated contact is close, it opens by activating
per remote control
11, 12
"12 V AC / DC"
11, 13
"24 V AC / DC"
14
Antenna
15
Screen
* You can set the K4 relay as ON/OFF or as an impulse via the JP1 jumper
(see figure 3.5.2-3). The setting depends on the control unit which is to be
triggered by the receiver.
• Relay remains active after being activated by
remote control.
• Deactivation by actuating the remote control
once more.
No. Name
JP1 jumper
P1 button
K4 relay
red LED
green LED