10. Defects - causes - remedies
WARNING! Electrical shock hazard!
Dangers caused by electrical energy must be excluded.
All electrical work must be performed after the electrical
supply has been switched off and secured against unau-
thorized switching.
WARNING! Risk of scalding!
At high water temperatures and system pressure close
isolating valves before and after the pump.
First, allow pump to cool down.
If the fault cannot be solved, please contact
Wilo customer services.
11. Spare parts
All spare parts must be ordered through Wilo Customer
Services.
In order to avoid any mistakes, please specify the name
plate data for orders.
Spare parts catalogue is available at www.wilo.com.
12. Safe disposal
Proper disposal and recycling of this product prevents
damage to the environment and risks to personal health.
Disposal in accordance with the regulations requires the
product to be drained and cleaned.
Lubricants must be collected. The pump components
are to be separated according to material (metal, plastic,
electronics).
1. Use public or private disposal organizations when dis-
posing of all or part of the product.
2. For more information on proper disposal, please con-
tact your local
council or waste disposal office or the supplier from
whom you obtained the product.
NOTE: The pump must not be disposed of along with house-
hold waste. Further information on recycling can be found at
www.wilo-recycling.com.
Subject to technical alterations!
Defects
Causes
Remedies
Pump fails to operate
No current
Check the fuses, the wiring, and the connectors
The thermistor tripping device has tripped
out, cutting off power
Eliminate any cause of overloading of the motor
Pump runs but delivers too little Wrong direction of rotation
Check the direction of rotation of the motor and cor-
rect it if necessary
Parts of the pump are obstructed by for-
eign bodies
Check and clean the pipe
Air in suction pipe
Make the suction pipe airtight
Suction pipe too narrow
Install a larger suction pipe
The valve is not open far enough
Open the valve properly
Pump delivers unevenly
Air in pump
Evacuate the air in the pump; check that the suction
pipe is airtight. If required, start the pump 20-30s –
open the air bleed screw in order to move air away
– close the air bleed screw and repeat it several times
until no more air is going out of the pump
Pump vibrates or is noisy
Foreign bodies in pump
Remove the foreign bodies
Pump not properly attached to ground
Retighten the screws
Bearing damaged
Call Wilo Customer Service
Motor overheats. Its protection
trips out
A phase is open-circuit
Check the fuses, the wiring, and the connectors
Ambient temperature too high
Provide cooling
Mechanical seal is leaking
Mechanical seal is damaged
Replace the mechanical seal