Replacing Fuses
Maintenance
50
Replacing Fuses
Replacing the Battery Bank Voltage Fuse
Overview
The WhisperGen
TM
detects the voltage of the battery bank via two wires
connected to the terminals of the battery bank as shown below.
If the battery bank voltage displayed on the control panel is abnormal, the
fuse in the circuit may have blown.
Before replacing a fuse, find out the cause of the fault.
Otherwise, damage to equipment may occur. If you are unsure of the cause
of the fault, contact your authorised WhisperGen
TM
service agent for
assistance.
Ensure that the replacement fuse is of a similar type (Ø0.25 x
1.25 inch, or Ø6.35 x 31.75mm) and of the correct current rating (2.00A). It
is advisable to keep spare fuses with the WhisperGen
TM
at all times.
Procedure
To replace the battery bank voltage fuse:
1. Unscrew the fuse holder.
FUEL
OFF
ON
Voltage Fuse
Voltage
Sensing
Wires
Fuse Holder
(Fuse Inside)
WTL0036
Personal Power Station
2. Replace the faulty fuse.
3. Fasten the fuse holder.
WhisperGen
TM
fuses can be obtained from electrical hardware suppliers or
your authorised WhisperGen
TM
service agent.