Procedures
Trouble Shooting
66
The following procedures may need to be carried out if faults develop:
Procedure
How
When
Bleeding the fuel line.
See section - Bleeding
the fuel line.
When there is air
trapped in the fuel line.
After a fuel run-out
occurs.
After the fuel filter is
cleaned.
Cleaning the fuel
pump filter.
See section - Cleaning
the fuel pump filter.
When fuel supply faults
arise.
When the power output
is constantly low.
Bleeding the coolant
circuit.
See section - Bleeding
the coolant circuit.
When there is a block
over temperature fault.
Replacing the glow
plug.
See section - Replacing
the glow plug.
When a glow plug
circuit fault arises and
the glow plug fuse is
not blown.
Replacing fuses.
See section - Replacing
fuses.
When fuses are blown.
Replacing the FID.
See section - Replacing
the FID
When ignition or flame
faults occur repetitively.
Replacing the oxygen
sensor.
See section - Replacing
the oxygen sensor.
When oxygen sensor
faults arise.
If burner or flame faults
occur despite FID
replacement.
Replacing the
evaporator.
See section - Replacing
the evaporator.
If burner, ignition, or
flame faults occur
despite FID and/or
oxygen sensor
replacement.
For all WhisperGen
TM
faults and maintenance procedures not listed in this
manual, please contact your authorised WhisperGen
TM
service agent for
assistance.
When maintaining or troubleshooting the WhisperGen
TM
, only
perform the procedures recommended in this manual. If you perform other
procedures, you may cause injury or equipment damage, and the warranty
on the WhisperGen
TM
will be void.