Operation
Managing Heat Generation
27
The WhisperGen
TM
will continuously maintain the coolant temperature after
the battery bank is fully charged only if the system is started manually or
from a remote switch. If the WhisperGen
TM
starts as a result of the Auto-
charge function, the system will stop and return to the standby mode once
the battery bank is fully charged. For more information refer to the Quick
Reference section in the User Manual.
To turn on the heat management option:
1. Access
the
User Menu
on the control panel. Access the default display
on the control panel by pressing
Left Arrow
repeatedly.
Battery Watts
2. Press
Right Arrow
to display the first item on the main menu, the
User
Menu.
User Menu
3. Press
Right Arrow
to display the first item on the User Menu.
Heat Manage
4. Press
Right Arrow
to begin editing the heat management setting.
5. Press
Up Arrow
to turn the Heat Manage option ON. The
HEAT
MANAGE
indicator lights up.
R
Optional:
press
Left Arrow
repeatedly to return to the default display.
You can also let the default display re-appear automatically by allowing a
few minutes of inactivity on the control panel.
With the
Heat Manage
option turned
ON
, the WhisperGen
TM
, if started
manually or from a remote switch, will run continuously and maintain the
coolant temperature until it is stopped manually or from the remote switch. If
a
Max Run Hours
setting of less than
25
has been set, the WhisperGen
TM
will automatically stop when the
Max Run Hours
set value is reached. See
the Quick Reference in the User Manual for a summary of operating options.
Содержание PPS16-12MD
Страница 1: ...user s manual Part Number WP 5012 001 01 ...
Страница 2: ......
Страница 4: ......
Страница 8: ......