Managing Heat Generation
Operation
26
Managing Heat Generation
Setting the Coolant Temperature
Whenever it is running, the WhisperGen
TM
regulates the temperature of the
coolant circulating through it. The coolant is used for space and domestic
water heating. By default, the temperature of the coolant is maintained at
approximately 60°C. You may, however, set the coolant temperature to any
temperature from 45°C to 70°C.
To set the temperature of the coolant:
1. Access
the
User Menu
on the control panel. Access the default display
on the control panel by pressing
Left Arrow
repeatedly.
Battery Watts
2. Press
Right Arrow
to display the first item on the main menu, the
User
Menu.
User Menu
3. Press
Right Arrow
to display the first item on the User Menu.
Heat Manage
4. Press
Down Arrow
to scroll down to
Temp Setpoint
.
Temp Setpoint
5. Press
Right Arrow
to begin editing the coolant temperature setting.
6. Press
Up Arrow
or
Down Arrow
to select the coolant temperature. The
values shown on the control panel are in °C.
Temp Setpoint 62
Optional:
press
Left Arrow
repeatedly to return to the default display.
You can also let the default display re-appear automatically by allowing a
few minutes of inactivity on the control panel.
Turning On Heat Management
The WhisperGen
TM
maintains the coolant temperature at the set point until
the battery bank is fully charged when it is running. When the battery bank is
fully charged, the system stops and returns to the standby mode and the
coolant temperature is no longer maintained.
However, you can however turn on the Heat Management option to keep
the system running to maintain the coolant temperature continuously even
after the battery bank has been fully charged.