ActiveScale™ P100 Support Guide
37
2. From the rear of rack with the label facing down, insert the SFP+ transceiver into the SFP+ port on the
System Node.
3. Close the latch on the SFP+ transceiver.
Figure 3-22. SFP+ transceiver installation
4. Insert both of the fiber optic cables into the replacement SFP+ transceiver.
5. Check to make sure that the activity LED on the port where the SFP+ transceiver replacement
occurred is blinking steadily. This behavior confirms that data is being transmitted along that port.
3.1.4 Replacing System Nodes
Caution:
The System Node weights
27 lbs (12.2 kg)
. Take precautions when
handling the System Node.
Caution:
Disconnect all power sources before servicing.
Caution:
Verify that the power cables are not damaged. If they are damaged, they
may be a shock hazard and the system may need to be shutdown to replace the
server.
Press
Press