Multi-Beam Safety Light Array
107
f) Full Muting Enable
OSSD
RES
SIG LOW
ERROR
Switch on
• The “Full Muting Enable” function is suitable for use, in conjunc-
tion with “partial muting”, for applications where the object height
varies.
– ON: Partial muting is lifted when a signal is applied and muting
acts on the entire safety field height.
– OFF: Partial muting is active without changes to the safety field
height.
• This function should only be used if “Partial Muting” was activat-
ed beforehand.
• For more information on the “Full Muting Enable” function, see
OSSD
RES
SIG LOW
ERROR
Switch off
OSSD
RES
SIG LOW
ERROR
Back
OSSD
RES
SIG LOW
ERROR
g) Gap suppression
OSSD
RES
SIG LOW
ERROR
Switch on
• For transport items with gaps, brief interruptions in the muting
signal are to be expected. The “gap suppression” function pre-
vents this from ending the muting function.
– ON: The muting signals (MS1…MS4) are delayed by 250ms.
– OFF: No muting signal delay
• For more information on the “gap suppression” function, see
OSSD
RES
SIG LOW
ERROR
Switch off
OSSD
RES
SIG LOW
ERROR
Back
OSSD
RES
SIG LOW
ERROR
h) Override
OSSD
RES
SIG LOW
ERROR
Switch on
• The “override” function enables the OSSDs to be enabled if a
penetration of the safety field is detected and the muting se-
quence is not valid.
• This can be necessary if a valid muting sequence is interrupted
(due to a conveyor belt stop, for example).
– ON: Override activated.
– OFF: Override deactivated.
• For more information on the “override” function, see
OSSD
RES
SIG LOW
ERROR
Switch off
OSSD
RES
SIG LOW
ERROR
Back
OSSD
RES
SIG LOW
ERROR