Multi-Beam Safety Light Array
71
5.2.4.7.8 Full Muting Enable
For applications where the object height varies, the muting can be extended to the total safety height of the
ESPE at specific times with the “Full Muting Enable” function. This function should only be used if “Partial
Muting” was activated beforehand.
Usage condition
Condition
Comment
1.
“Full Muting_Enable” is parametrized.
Basic requirement for activating the function.
2.
Signal_Full-Muting_Enable, MS1 and MS2 are not
active.
3.
Signal_Full-Muting_Enable becomes active, MS1
and MS2 are inactive.
The signal Signal Full-Muting_Enable must be
active until both muting signals are applied and
muting is activated.
4.
MS1 and MS2 become active within 30 seconds
and muting is therefore active.
The following figure shows the signal path for the individual steps.
Signal_Full-
Muting_Enable
Full Muting
active
Figure 15: Valid signal sequence for activating Full Muting Enable
NOTE!
• The activation of the “Full Muting Enable” function via a valid signal sequence causes the
following muting cycle to take place over the entire height of the ESPE. It does not initiate
a muting cycle itself, however.
• Once the muting cycle is complete, the function is no longer active and the usage condi-
tions must be repeated for another “Full Muting”.
• The “Full Muting Enable” function uses the same input as the “Belt Stop” function.