Multi-Beam Safety Light Array
17
SEFB muting
SEFB
Functions
Body protection
Yes
Safety operating mode
Yes
Restart inhibit
Yes
Contactor monitoring
Yes
Muting
Yes
No
Cascading
Yes
No
The following table specifies the tightening torques of the plugs and mounting options in order to assure
compliant, error-free operation:
Connection type
Tightening torque (Nm)
M12
0.4
4.2 Response Times
SEFB muting
SEFB
Beam distance
[mm]
Number of beams
Response time
[ms]
SEFB412
SEFB422
500
2
15.0
SEFB413
SEFB423
400
3
15.0
SEFB414
SEFB424
300
4
15.0
4.3 Weight Tables
SEFB muting
SEFB
Beam distance
[mm]
Number of beams
Max. weight per
component [kg]
SEFB412
SEFB422
500
2
1.22
SEFB413
SEFB423
400
3
1.79
SEFB414
SEFB424
300
4
2.00