Diagnosis
142
13.2.2 Error Indicator on the Receiver SEFB
Error
Display
Action
RES
EDM
CODE
ERROR
Parametrization not
complete (timeout)
RES
EDM
CODE
ERROR
• Carry out parametrization in accor-
LED lit
LED lit
LED lit
LED lit
Internal error
RES
EDM
CODE
ERROR
• Restart system
• Carry out parametrization in accor-
• Contact the wenglor support de-
partment if the error occurs again
LED off
LED off
LED off
LED lit
Error ambient light
RES
EDM
CODE
ERROR
• Remove the interfering emitter
• Check for and remove any other
extraneous light sources
LED off
LED off
LED lit
LED lit
Error OSSD1
RES
EDM
CODE
ERROR
• Resolve short to positive or short
to ground
LED lit
LED lit
LED off
LED lit
Error OSSD2
RES
EDM
CODE
ERROR
• Resolve short to positive or short
to ground
LED lit
LED off
LED lit
LED lit
Error contactor mon-
itoring – contactor
does not activate
RES
EDM
CODE
ERROR
• Check the contactor function
• Configure the EDM parameters
correctly
LED off
LED lit
LED off
LED lit
Error contactor mon-
itoring – contactor
does not deactivate
RES
EDM
CODE
ERROR
• Check the contactor function
• Configure the EDM parameters
correctly
LED off
LED lit
LED lit
LED lit
Over/undervoltage
RES
EDM
CODE
ERROR
• Make supply voltage available
within the specified limits
LED lit
LED off
LED off
LED lit
13.2.3 Error Indicator on the Receiver SEFB Muting
Display
Error
According to the diagnosis code in the segment display (see
1
OSSD 1 (red)
OSSD2 (green)
OSSD
LED lit
LED off
2
RES
RES
LED off
3
SIG LOW
SIG LOW
LED off
4
ERROR
ERROR
LED lit
Action