Factory Default configuration
3.2.1 Resetting WL-TX-900 to factory defaults
To reset the default factory configuration:
1. Set the rotary switch to position 0 using a screwdriver.
2. Power on the WL-TX-900 transmitter.
3. The WL-TX-900 transmitter flashes all LEDs at medium flash (i.e. 1.6 Hz).
If the LEDs do not flash, you must repeat steps 1 and 2 until the LEDs flash
before continuing.
4. Set the rotary switch to another position (i.e. position 1) within 5 seconds.
NOTE
5. Set the rotary switch to position 0 within another 5 seconds.
6. The WL-TX-900 transmitter lights all LEDs for 2 seconds before returning to
normal operation.
If the LEDs do not light for 2 seconds, you must repeat the process from step 1
until the LEDs light before continuing.
3.2.2 Resetting WL-RX-900 to factory defaults
NOTE
To reset the default factory configuration:
1. Press and hold the SIG push button.
2. Power on the WL-RX-900 receiver.
3. The WL-RX-900 receiver flashes all LEDs at medium flash (i.e. 1.6 Hz).
If the LEDs do not flash, you must repeat steps 1 and 2 until the LEDs flash
before continuing.
4. Release the SIG push button within 5 seconds.
NOTE
5. Within a further 60 seconds, press and hold the SIG push button until the LEDs
stop flashing (about 5 seconds) and then release.
6. The WL-RX-900 receiver lights all LEDs for 2 seconds before returning to normal
operation.
If the LEDs do not light, you must repeat the process from step 1 until the LEDs
light before continuing.
NOTE
29