Factory Default configuration
3
Factory Default configuration
3.1
Overview
This section describes the factory default configuration. You can configure your
network using:
Factory Default configuration – that lets you easily setup two units as a simple
send/receive; or
User-defined customized configuration – that lets you set more specific mappings
and links between multiple units. It requires a PC running the WL Series
configuration software provided and a special cable to connect to the units.
The default configuration links one WL-TX-900 and WL-RX-900 pair together. The
following table details the factory default configuration.
For information about using the WL Series Configuration software see section 4.
3.2
Default signal mappings
WL-TX-900(Transmitter)
WL-RX-900 (Receiver)
Digital Input 1
Digital Output 1
Digital Input 2
Digital Output 2
Analog Setpoint
Digital Output 3
Analog input (4-20 mA)
Analog output (4-20mA)
WL-TX-900(Transmitter)
Thermocouple Input (Not used)
Setpoint Output (Local indication)
System OK (On if system OK)
WL-RX-900 (Receiver)
Communication Failure
(On if no messages from WL-TX-900)
System OK (On if system OK)
28