3.0 Planning Your 2-Wire Layout
3.0 Planning Your 2-Wire Layout
The SmartWire™ SL9600TW 2-Wire Decoder Module allows you
to have several options in cable routing to determine the most
efficient 2-wire layout for your project. You can connect as
many as three 2-wire runs. Maximum decoder to valve distance
is 100 feet (30.5m).
Each 2-wire run can be laid out in Straight Run, Complete Loop,
Star, or Combination configurations as shown to the right.
It is suggested that a continuous loop be laid out around the
site. This usually follows the main water lines. The loop will
start at the SmartLine® controller and continue around the
site and then return to the controller. This provides the best
communication and power path for the system. The loop
provides a redundant path for the power and signal allowing
the system to continue operation if the loop is cut.
Branches can come off the main loop and they do not need to
be looped back to the main trunk line. These branches can be
other loops, stars or single dead-end lines. The system will work
with most wiring configurations if the wire length requirements
are met. (Note: Keep BLACK to BLACK and RED to RED when
wiring the communication wire.)
Straight Run
Decoder
Last
Decoder
Decoder
SL9600TW
Decoder
Decoder
Decoder
Complete Loop
Water Source
Main Line
SL9600TW
Last
Decoder
Star
SL9600TW
Last
Decoder
Last
Decoder
Last
Decoder
Last
Decoder
Combination
SL9600TW
Last
Decoder