7
http://support.weathermatic.com
4.0 Lightning Protection
1 Station
To SLM48DM
SLCONN
Waterproof
wiring connector
Common
Wire
2 Station
4 Station
Common
Wire
4.0 Lightning Protection
Weathermatic SLGDT gas discharge tube lightning arrestors
must be used on all 2-wire grids. The SLGDT lightning arrestor
attaches directly to the 2-wire system and helps dissipate
static electricity generated by a nearby lightning strike. While
Weathermatic components have lightning arresting features,
the SLGDT provides an extra measure of protection.
4.1 SLGDT Lightning Arrestor Features
• Protects the 2-wire system from excessive static charges
created by a lightning strike.
• Sealed and impervious to moisture, salts, fertilizers and mild
chemicals. Can be buried directly in the soil.
• Shock resistant
• Freeze/heat resistant (-20° to 60° C)
• No electrical contact with the soil
• Each Lightning Arrestor protects a 300 foot radius
4.2 Electrical Specifications
• Requires no power from the 2-wire system
• Can only be connected to SmartWire™ 2-wire systems
4.3 Installating the SLGDT Lightning Arrestor
1. Connect the RED and BLACK lead wires to the 2-wire system
RED and BLACK wires.
2. Attach the GREEN ground wire to Earth Ground (Grounding
Requirements below)
SL9600TW
Decode
Lightning Arrestor
2-Wire Path
600’ Max
1
4
3
1
2
600’ Max
50’ Max