20
http://support.weathermatic.com
10.0 Advanced Menu
10.1 FAULT
This feature is used to identify problems that may require
attention or repair to insure proper operation of the system.
Use NEXT button to view the type of fault. If more than one
fault exists, you can use the UP and DOWN buttons to search
for additional faults. Use NEXT button one more time and it
will flash KEEP. If you want to clear the fault, use the UP and it
will flash CLEAR. If you turn the dial out of the Advanced Menu
positions while CLEAR is flashing, the fault icon on the display
will disappear. However, if the cause of the fault is not corrected,
the controller will continue to skip watering a zone with a fault
and will resume the flashing FAULT icon on the display each
time that zone is operated.
SCROLLING FAULT
MESSAGE
FAULT DESCRIPTION
ZONE XX SHORT OUTPUT SHORT CIRCUIT: A load placed
on any output that results in a current
draw exceeding the skip current setting
will result in a fault aer the output is turned
on. The output will be skipped until the
next watering program attempts to use
it. If the MV/P output is shorted, all zones
using it will effectively be skipped. The
fault indication can be manually cleared or
will be automatically cleared if the short
condition goes away and the output turns
on successfully.
SCROLLING FAULT
MESSAGE
FAULT DESCRIPTION
ZONE XX OPEN
OUTPUT OPEN CIRCUIT: If a zone has a
current draw less than 30 mA a zone open
fault is created, but operation continues
normally. The fault can be manually
cleared or will automatically clear if a load
exceeding 30 mA is placed on the output
and the output turns on successfully.
NO RECENT
CONTACT
WITH Weather
Sensor
COMMUNICATIONS FAILURE: If the
SmartLine® controller is in SMART mode
and the daily high/low temperature
has not been received by midnight, this
communication fault is set. Also, if the
battery in the SLW Weather Sensor is dead,
the communication fault is set. If 5 days
pass without communication, the controller
will revert to the BASIC mode Zone Run
Times. The fault indication can be manually
cleared or will clear automatically once
communication is received.
REMOTE
BATTERY
FAILURE
If the SmartLine® controller receives com-
munication from the SLW Weather Sensor
that indicates the remote battery is low,
the fault is set. The fault indication can be
manually cleared or will clear automatically
if the SLW Weather Sensor sends another
message that indicates a good battery. The
fault will also clear if no communication is
received for a full day (i.e. communication
failure). See Section 7.3 Replacing SLW
Series Weather Sensor Battery.