GRANUDOS Touch, control unit
Index: 02
Date modified: 11/06/2019
OI No.: BA SW 010-02 Granudos Touch-Steuereinheit EN SCHW 8.docx
Page 20 of 43
NOTICE!
Please reduce the background lighting to the minimal brightness required by you. This
increases the service life of the display significantly.
d)
Main menu
Settings
System
Network
The touch panel has a LAN interface with RJ45 socket. The current
status messages can be transferred to an external display via this
interface. The terminal device can be a PC monitor, a tablet PC or a
smartphone, e.g.
Further information about this topic is available upon request. The
operator must establish the necessary IT requirements for remote
access! (e.g., VNP connection, data security, etc.)
e)
Main menu
Settings
System
Reset
This order can only be performed in user level 2.
All of the set parameters are reset here to the factory settings.
The factory settings are listed in the operation data sheet
in Section 9.4
After “reset” all individual setting must be set again!
f)
Main menu
Settings
System
Lanuage
Select the desired operating language.
Main menu
Settings
Determining dosing performance
The effective dosing performance must be determined in order to
calculate chemical consumption and thereby the reserve message.
Follow the menu prompts. A dosing sample is taken 3 times.
NOTICE!
Place a shallow collecting vessel under the dosing pipe and follow the menu prompts.
Weigh the dosing sample.