GRANUDOS Touch, control unit
Index: 02
Date modified: 11/06/2019
OI No.: BA SW 010-02 Granudos Touch-Steuereinheit EN SCHW 8.docx
Page 38 of 43
9.3
Commissioning protocol
See operating instructions Part 1 Dosing technology, regarding the respective dosing device.
9.4
Operation data sheet
During a
"firmware update,"
all parameters are reset to the factory setting. After an "update," all parameters
must therefore be checked and readjusted to the basin. We therefore recommend that you enter the
optimised, basin-specific parameters in this list.
In addition, the electrodes must be calibrated after a
"firmware update!"
Settings menu
Factory setting
Setting ranges
Step
during
commissioning
Optimised
during
operation
1 Dosing performance
pH/acid
Date:
Date:
Acid
8 seconds
1-8 seconds
1
Chlorine
15 seconds
1-15 seconds
1
Cycle
30 seconds
30-360 seconds
30
Dosing time limit acid
0
0-100 minutes
5
Dosing time limit chlorine
0
0-100 minutes
5
Manual dosing
Off
Off – On
2 Reserve indication
chlorine
Reserve message
like order
1-150 kg
1
container size
like order
1-150 kg
1
Reserve indication
On
Off - On
3 Reserve indication acid
Reserve message after
20l
1-500l
1
Container size
25l
1-500l
1
Reserve indication
On
Off - On
4 Shock cl.
Dosing performance acid
10%
10-100%
1
Dosing performance chlorine 50%
0-100%
1
5 System
Password
End user
----
0000 – 9999
1
Technician 1
01234
00000 – 99999
1
6 System
Display
Screensaver
20%
12-100%
2
Delay
00:05
00:00 – 23:59
Backlight
75%
24 - 100%
2
7 System
Network
IP-address
192.168.0.1
Gateway
192.168.0.0
Subnet
255.255.255.0
8 Dust extraction (option)
Flushing interval
12h
0 – 48h
1
Flushing time
5 seconds
0 - 5 seconds
1
Dust extraction
like order
Off – On
9 Buffer tank (option)
Dosing performance acid
10%
10 - 100%
1
Dosing performance chlorine 50%
50 - 100%
1
Activate buffer tank
like order
Off – On