63899-002 Rev. A 3/20/2024
16
Figure 6
G. MAIN BURNER INSTALLATION
The LC2300M power gas burners are approved for use with natural and LP gas only.
G.1 GENERAL INSTRUCTION
Installation must be completed in accordance with current instructions. The installer must be familiar
with all regulations, so the installation meets the necessary requirements of the local authorities.
Installation, assembly, and set up must be performed to obtain optimal function. Only gas intended for
the burner may be used.
G.2 INSPECTION AND PREPARATION
It is the installer’s responsibility to instruct the end user about the functions of the burner and the entire
system. The system must be maintained following the timeline specified by the service schedule found
in SECTION IV - SERVICE. If the burner is in an unclean environment, cleaning and service should be
done on a more frequent schedule. Check that the overall burner size and capacity meet that of the
intended application.
G.3 GAS AND ELECTRIC CONNECTION
To maintain operational safety, there are a few points that must be considered. The burner and its
components must also be approved for the specified gas pressure. All installations for the burner must be
carried out in accordance with current standards. All gas lines should be installed so that any routine
service and maintenance can be easily performed on both the burner and the intended application.
Before installation, all electrical connections must be disconnected. This allows the burner installation to
be electronically isolated. Connections must be made according to current regulations. Electrical
connections must conform to the wiring diagram provided.
H. BURNER SETUP
Table 1: LC2300M with 1 ½” Gas Line - Natural Gas
(Siemens VGD 1” Double Valve Body with SKP15 and SKP25 Regulators)
Firing
Rate
(1000’s
Btu/hr)
Combustion
Air Shutter
Setting (0-
90*)
Butterfly
Valve
Gas
Actuator
Setting
(0-90*)
Target
O
2
(%)
Manifold
Pressure
Inch of
Water
Minimum Inlet
Pressure
Inch of Water
(Burner Running)
Dimension
“A”
Setting
(Figure 6)
57
0
4.5
3-4
9
10
3-3.25”
110
0
10
3-4
9
10
3-3.25”
250
5.0
17
3-4
9
10
3-3.25”
550
26.5
30
3-4
9
10
3-3.25”
1000
42.5
43.5
3-4
9
10
3-3.25”
1400
57
52
3-4
9
10
3-3.25”
1800
68
58.5
3-4
9
10
3-3.25”
2000
82.5
66.5
3-4
9
10
3-3.25”
2300
90
75
3-4
9
10
3-3.25”
*For all firing rates above, a yellow regulator spring, part #1000176 (provided) is used.
Содержание LC2300M
Страница 35: ...63899 002 Rev A 3 20 2024 35 B WIRING DIAGRAM...
Страница 36: ...63899 002 Rev A 3 20 2024 36...
Страница 57: ...63899 002 Rev A 3 20 2024 57...
Страница 58: ...63899 002 Rev A 3 20 2024 58...
Страница 59: ...63899 002 Rev A 3 20 2024 59...
Страница 60: ...63899 002 Rev A 3 20 2024 60...
Страница 63: ...63899 002 Rev A 3 20 2024 63 This page intentionally left blank...
Страница 64: ...63899 002 Rev A 3 20 2024 64 NOTES...