Model 452:
Perform the fol lowing adjustments:
Go in/Phase me te r
connected between:
::::
- A l ternate ly adjust :
to obtain Gain (dB):
and Phase (deg):
B - Adj ust:
- to obtain Gain (dB):
C - Adj ust:
- to obtain Gain (dB):
T P-l
&
T P-2
C29
&
C34
-4. 1 ± 0 . 2
9 0 ± 1
T P-2
& OUT
C39 & C44
+9 . 3 ± 0 . 2
90
±
3
Model 852:
Perform the fol lowing adjustments:
TP-l
TP-2
T P -3
Gain/Phase meter
&
&
&
connected between:
T P-2
T P-3
T P-4
�
-
A l ternately Adjust :
C29
&
C34
C39
&
C44
C49 & C54
to obtain Gain (dB):
-5 . 5 ± 0 . 2
-1 .9 ± 0 . 2
+4 . 6 ± 0 . 2
& Phase (deg):
90 ± 1
90 ± 1
90 ± 2
�
- Adj ust:
to obtain Gain (dB):
s:
- Adj ust:
to obtain Gai n (dB) :
4- 18
IN & OUT
C39
&
C44
-3 . 0 ± 0.2
1 80 ± 4
R 1 6
0 . 0 + 0 . 1
R2 1
-3 . 0 ± 0 . 0
TP-4
&
OUT
C59 & C64
+1 6 . 5 ± 0 . 2
90 ± 6
I N
&
OUT
C59
&
C64
-3 . 0 ± 0 . 5
1 80 ± 8
R 1 6
0 + 0 . 2
R33
-3 . 0 ± 0 . 0