8.4 Check the Hydraulic Oil Level
Check hydraulic oil level daily.
The hydraulic oil tank sight
glass is on the front of the tank. Check level with the engine
stopped.
The proper level is when the oil fills the glass window.
If the
level is not visible in the sight glass, add oil.
00323
Fig. 40 –
Hydraulic Tank Oil Level Check
1. Hydraulic Tank Filler Cap
2. Oil Level Sight Glass
IMPORTANT! Do not operate machine if oil level is not
visible in the sight glass. Damage to the pump and other
components can occur.
Do not overfill the tank past the sight glass window.
IMPORTANT! Hydraulic oil quality should be inspected
every 50 hours. If the oil is dirty or smells burnt, it should be
replaced.
IMPORTANT! Be aware of high oil temperatures.
Temperatures higher than 180 °F (82 °C) could cause seal
damage and degrade oil quality.
8.4.1 Add Oil to the Tank
The hydraulic system uses
Dexron® III ATF
.
Procedure:
1.
Clean the area around filler cap and remove it.
2.
Use a clean funnel and add oil until the level just fills the
sight glass window.
3.
Install filler cap securely. Wipe up any spilled oil.
Check levels after changing filters or servicing hydraulic
components.
8.5 Check the Chain Saw Bar Oil
Level
Check bar oil level regularly.
The bar oil reservoir is located on
the left-hand side of the processor. Oil level is visible in the tube
on the side of the reservoir. Reservoir capacity is 6-1/2 quarts
(6.2 L).
Your cutting system operates in a challenging environment and
depends on sufficient lubrication to minimize wear and extend
the life of operation. At start up, allow adequate time for the oil
from the reservoir to reach the cutting system.
01799
Fig. 41 –
Bar Oil Reservoir
Bar and chain oils provide adequate lubrication to the cutting
system when used correctly.
IMPORTANT! The cutting system must use chain saw bar
oil only. Hydraulic or engine oils do not provide adequate
lubrication. Non-approved lubricants can void saw warranty.
8.6 Check the Saw Chain
Check saw chain tension regularly.
To tension the saw chain,
00369
Fig. 42 –
Saw Access Door