12.3 Change the Hydraulic Oil
CAUTION!
Risk of burns to exposed skin.
Hydraulic oil becomes hot during
operation. Hoses, lines, and other
parts become hot as well. Wait for
the oil and components to cool
before starting any maintenance or
inspection work.
W028
Change the hydraulic oil in the reservoir at
100 hours
of
operation or annually.
•
Hydraulic oil type:
Dexron III ATF.
•
Hydraulic oil tank capacity:
26 US gal (102 L)
The hydraulic tank drain plug is located under the machine. A
3/8" Allen wrench is required to remove it.
01058
3/8"
Fig. 77 –
Hydraulic Tank Drain Plug
Procedure
1.
Have a drain pan ready of suitable capacity.
2.
Clean the area around drain and remove the drain plug.
3.
Allow the oil to fully drain, then flush the tank. Dispose of
used oil in an environmentally acceptable fashion.
4.
Install the drain plug.
5.
Change the return oil filter before filling the tank.
12.3.1 Change the Hydraulic Return Oil
Filter
The hydraulic return filter is located on top of the hydraulic oil
tank.
A bypass indicator gauge is located above the engine controls
on the side panel. If the gauge indicates the filter is bypassing,
the filter is clogged and must be changed at the time the oil is
changed.
01439
Fig. 78 –
Return Filter Bypass Indicator Gauge
Procedure
1.
Remove the hydraulic cover.
00321
Fig. 79 –
Hydraulic Oil Reservoir Cover
2.
Have a drain pan ready to catch any dripping oil.