S
TARTING
UP
AND
OPERATING
C
HAPTER
7
THP 94/42 R 4 XXT
THP 125/42 R 4 XXT
THP 140 H/42 R 4 XXT
GB-07.2005
7-17
7.5.3
“Pump/Suck” control by radio
remote control / cable remote
control
The operating mode selection switch (Item 14, Fig. 7.6)
must be set to “Radio remote control”.
The rocker switch (Item 12, Fig. 7.21) on the remote control
pendant is pre-set to “Pump” or “Suck”. Select “Pump” or
“Suck” using the rocker switch (Item 13, Fig. 7.21).
The stroke rate depends on the setting of the stroke rate
potentiometer (Item 11, Fig. 7.22) and the engine speed.
NOTE:
Opening the safety grill or pressing an Emergency Stop button (whilst the
“Pump/Suck” switch is activated), will deactivate the “Pump/Suck”
function, which must then be restarted by switching the rocker switch
(Item 13, Fig. 7.22) off and on again.
7.5.4
Back-up function for “Pump/Suck”
NOTE:
This function should only be switched on if the normal “Pump/Suck”
controls are not operational!
7.5.4.1
Pumping with the control panel desk or via radio remote control/cable remote control
•
Set the Back-up Pump control selector switch (Item 2, Fig. 5.7) to position “A or B”
If the pump does not start (see trouble-shooting), back-up operation may be necessary in two possible fault
situations:
11
12
13
14
Fig. 7.22 Operation "Pump/Suck" (radio remote control)