![Waitzinger THP 94/42 R 4 XXT Скачать руководство пользователя страница 104](http://html1.mh-extra.com/html/waitzinger/thp-94-42-r-4-xxt/thp-94-42-r-4-xxt_user-manual_3154061104.webp)
8 - 2
T
ROUBLE
-
SHOOTING
C
HAPTER
8
THP 94/42 R 4 XXT
THP 125/42 R 4 XXT
THP 140 H/42 R 4 XXT
GB-07.2005
Fault
Cause
Remedy
Emergency Stop indicator lamp
Emergency Stop button has been
Establish why the Emergency Stop
flashing.
pressed.
button was pressed and remedy
the cause.
Release the Emergency Stop and
restart the controls with the horn,
see section 7.2.2.
Selector switch set to remote
Release remote control Emergency
control.
Stop, or change over the selector
switch on the desk, and start the
controls with the horn.
Broken cable or defective
Have fault rectified by
Emergency Stop switch.
WAITZINGER
customer service.
Pumping or sucking does not
Selector switch in position
Move selector switch to position
start, no pressure available.
“Desk”.
“Remote control”, operate horn.
Grill open.
Close grill. Check limit switch.
“Pump ON” was selected when
Switch the pump off and
the controls were switched
restart it.
on using the horn.
Engine not running.
Start the engine.
Vehicle gearbox in neutral.
Select a gear, see section 7.2.1.
Stroke rate potentiometer at “0”.
Set a higher value, see
section 7.2.1.
Emergency Stop button has
Establish why the Emergency Stop
been pressed.
button was pressed and remedy
the cause.
Release the Emergency Stop and
restart the controls with the horn,
see section 7.2.2.
Hydraulic oil too hot.
Let the hydraulic system cool
down, see section 7.6.4.
Spool valve defective.
Check valve and solenoid, and
have part replaced if necessary
by
WAITZINGER