Check the lubrication pipes for damage and leak-tightness. All lubrication pipes must be securely connected.
5. Checking the grease nipples for manual lubrication
No grease must be leaking from the grease nipples. Either replace the defective grease nipple and non-return
valve immediately (or close it off).
6. Lubricating “manually”
CAUTION:
Before starting work, check that grease is issuing at all grease points,
see point 2.
If the central lubrication system is defective, all grease points can be lubricated manually, using a grease gun. This
should be performed no less frequently than every 2 hours of operation.
7. Blocked grease points
If no grease can be injected into a lubrication point, this problem must be rectified as soon as possible by a
WAITZINGER
customer service fitter.
CAUTION
6
6
4
5
6
6
3
2
1
7
3
5
4
1
Control pin
2
1T
1T
2T
2T
6T
6
Oscillation cylinder
7
Swing lever
Fig. 9.2 Lubrication system