8 - 8
T
ROUBLE
-
SHOOTING
C
HAPTER
8
THP 94/42 R 4 XXT
THP 125/42 R 4 XXT
THP 140 H/42 R 4 XXT
GB-07.2005
Fault
Cause
Remedy
Pressure setting at the agitator
Check pressure setting to data
control block is too low.
sheet, adjust as necessary.
Clean the pressure relief valve.
Seek advice from
WAITZINGER
customer service on this point.
Dirt in the water pump.
Disassemble the water pump
and clean it. See separate user
manual from the manufacturer.
Axial play in the pump shaft
Undo the coupling and adjust
incorrect.
to the mid value.
Lubrication system does not
Fuse blown.
Replace fuse.
operate.
Pump switched off.
Switch the pump on.
Grease too stiff.
Replace grease with suitable
grease, see Figure 9.5.
Lubrication point blocked.
Clear the blockage at the
lubrication point.
Lubrication distributor blocked.
Replace the grease up to the
lubrication distributor and replace
the lubrication distributor.
Pump impeller defective.
replace pump impeller.