S
TARTING
UP
AND
OPERATING
C
HAPTER
7
THP 94/42 R 4 XXT
THP 125/42 R 4 XXT
THP 140 H/42 R 4 XXT
GB-07.2005
7-2
b.
General information for operating the truck-mounted concrete pump
The operator must be familiar with and comply with the user manual and all safety measures for operating the
truck-mounted concrete pump. He must be able to control the machine.
b.1
Before starting up
墌
Secure the working- and hazard area and barrier it off if necessary
墌
Top up the fluids (hydraulic oil, fuel, water)
墌
Check the functioning of all safety devices - and controls
墌
Lubricate all grease points and check that the lubrication system is functioning
墌
Check the stability of the machine
墌
Check the conveying pipes for alignment and degree of wear (wall thickness measurement)
b.2
During operation
墌
Never allow the machine to operate unattended
墌
Stop the machine immediately if any fault occurs that might create a safety hazard
墌
In the event of blockages the material must be return to the hopper immediately. Start up again slowly!
墌
Open the snap couplings on the conveying pipes only when the conveying system has been depressurised
墌
When opening pipe joints, wear safety glasses to protect the eyes from spurting concrete
墌
Never reach into or on to moving parts, first switch the engine off or depressurise the accumulator
墌
Do not modify any safety device
b.3
At the end of operations
墌
Empty the conveying pipes
墌
Clean the conveying pipes using a cleaning ball and water
墌
Clean the hopper and the complete machine
墌
Perform routine maintenance, and repair any faults that have developed whilst the machine was running