29
VM 5000
OPERATING MANUAL
EDITION 07/2014
ORDER NUMBER DOC 2344501
C14 Operating mode
This parameter
is linked to
parameter C11.
If parameter
C14 is set,
parameter C11
is automatically
switched to "off ".
off
(factory setting)
Operation with GM 5000EA or GM 5000EAC manual spray gun
2
Automatic electrostatic spray gun
3
High voltage Universal 3 G cascade
4
High voltage Universal 7.5 G cascade
C15 Lock gun
operating button
off
(factory setting)
Lock is switched off
1
Partial Lock the gun operator button:
- Standby function disabled.
- Recipe change is possible.
2
Partial Lock the gun operator button:
- Recipe change are disabled.
- Standby is possible.
3
Full Lock the gun operator button:
- Recipe change are disabled.
- Standby function disabled.
C19 Reset recipes
no
(factory setting)
No reaction
res
All programs are set to delivery condition, if "res" is saved with
the "Service" button.
C20 Reset
confi guration
no
(factory setting)
No reaction
res
All confi guration parameters are set to delivery condition
(factory setting), if "res" is saved with the "Service" button.