OPERATING MANUAL
EDITION 07/2014
ORDER NUMBER DOC 2344501
6.9.1
MAINTENANCE COUNTER SET UP AND READING
When using the device for the fi rst time, the function for the maintenance hours counter is
deactivated. This function can be activated with the "R3" push button (3). The maintenance
interval limit can be set within a range of 0 to 999 hours.
Setting and saving the service interval limit in hours
Procedure:
1. Press the push button (3) briefl y.
Illuminated display (6) lights up.
2. Use the control dial (16) to set the
maintenance interval limit you
want (e.g. 90 hours).
3. Check setting on the display (15).
4. The value can be saved by
pressing and holding the push
button (19) until the indication in
the display (15) starts fl ashing.
Review counter reading since last service carried out on the gun
Procedure:
1. Press the push button (2) briefl y.
Illuminated display (5) lights up.
2. Read display (15). In the example,
46 hours have passed since
realization of the last spray gun
service.
The vertical graph on the left
indicates that 50% of the set
interval time has passed.
3. By pressing and holding the
push button (19), you can reset
the display (15) to 0 (reset upon
expiry of set interval limit).