39
VM 5000
EXT
100
80
60
40
20
μA
80
60
40
20
10
kV
R3
R1
R2
VM 5000
B_03682
_12
OPERATING MANUAL
EDITION 07/2014
ORDER NUMBER DOC 2344501
4. The control unit is ready for operation.
Note:
Each starting sequence is concluded
by allocating the saved set data in
recipe "R1".
7.4
SETTING AND SAVING RECIPES
Set values for the high-voltage (kV) and for the spray current limiting (μA) are stored in
a recipe. By default, the following values are saved at the factory in the 3 storage places
available for recipes:
Recipe No.
Set value - high-voltage in kV
Set value - spray current limiting in μA
R1
70 100
R2
60
100
R3
40
80
Recipes 1-3 can be selected and saved directly with the program buttons "R1", "R2" and
"R3". Once the recipe required has been called up, the individual coating parameters can
be called up and modifi ed with the corresponding selection buttons (see Chapter 7.2.1
and 7.2.2). When a parameter is changed, the LED on the left of the program button goes
out and indicates to the user that a parameter value has been changed.
The process for saving parameters is described below.
To reuse the originally set values, press the program button briefl y.
The modifi ed values are not taken over.
However if the modifi ed values should be saved, press and hold the corresponding
program button for approx. 2 seconds, until the LED beside the button starts to fl ash
quickly.
The modifi ed values are then saved.