45
VM 5000
EXT
100
80
60
40
20
μA
80
60
40
20
10
kV
R3
R1
R2
VM 5000
B_03271
1
2
3
4
5
16
21
6
7
19
20
22
17
18
13
8
9
12
14
11
10
15
OPERATING MANUAL
EDITION 07/2014
ORDER NUMBER DOC 2344501
8
TROUBLESHOOTING AND RECTIFICATION
Functional fault
Cause
Remedy
No illuminated display lights up
Mains supply not switched on
Check and switch on mains supply
Fuses defective
Replace fuses
Wagner Service
No high-voltage
Spray gun cable not connected or
defective
Connect spray gun cable
Spray gun not connected or defective
Wagner Service
Excessive conductivity of the lacquer
See operating manual of spray gun
Fault LED (12) lights up
Fault message in display (15)
See the following table
See the following table