OPERATING MANUAL
EDITION 07/2014
ORDER NUMBER DOC 2344501
Code
display
Fault
Cause
Remedy
E11
Ground monitoring
Grounding cable is interrupted
Check/replace gun cable
Check/replace gun
Gun is not connected
Connect gun
E12
No coil current/
cascade interrupt
Gun is not connected
Connect gun
Gun cable is interrupted
Check/replace gun cable
Cascade in gun is interrupted
--> defective
Check/replace gun
E13
Coil current too big
Cascade of the connected gun is
defective
Check/replace gun
E21-E29 Exception error
Hardware defect has occurred
If problem persists, contact Wagner
Service Team
E30
Cabinet door
monitoring
In Aquacoat operation: switching
on the high-voltage with an open
door
Close Aquacoat cabinet door
E40-E43 Gun communication
faulty
Gun cable defective
Check/replace gun cable
Operating unit of spray gun defective
Wagner Service
Control unit defective
Wagner Service
E60
Password error
Password not set
Password to be set by Service Center
The fault LED (12) indicates faults. In addition, the error number is shown in the 7-segment
display (15). If a fault occurs, high-voltage is immediately switched off . Work can only be
continued once the error has been remedied and acknowledged with the "Service" push
button (14).