33
VM 5000
EXT
100
80
60
40
20
μA
80
60
40
20
10
kV
R3
R1
R2
VM 5000
B_03682
_08
15
14
13
4
1
OPERATING MANUAL
EDITION 07/2014
ORDER NUMBER DOC 2344501
6.9
OPERATING HOURS COUNTER / SERVICE DISPLAY
Two hour counters are integrated into the control unit. The absolute counter measures the
spray gun's current operating hours and with the maintenance hours counter, the spray
gun's maintenance intervals can be determined and monitored.
When the control unit is in the ready position, you can access the maintenance menu
screen using the push button (14).
Maintenance menu structure (illuminated display (13) is activated)
Push
button
Description of display
R1
Display of the spray gun's absolute accrued operating hours.
Display format:
Counter reading < 999 hours: 001 = 1 h; 291 = 291 h
Counter reading < 1000 hours: 1.23 = 1230 h; 45.2 = 45200 h
Maximum display value = 99.9 = 99900 h
Afterwards it shows fl ashing dashes.
R2
Display of temporary maintenance counter and
how to reset this counter
R3
Setting the maintenance interval in hours or
activation or blocking of this function