FAULTS
Faults are indicated by fault LED 13 lighting up. In addition, the error number "Exx" (xx
stands for the fault number) is shown in the LED display 19 (7-segment LED). If a fault
occurs, high-voltage, air, etc. is immediately switched off . Work can be continued only after
removing the fault and pressing any button.
Fault number
Fault
Cause
Remedy
E11
Ground monitoring
Grounding cable is
interrupted
Check/replace gun cable
Check/replace gun
Gun is not connected
Connect gun
E12
No coil current/
cascade interrupt
Gun is not connected
Connect gun
Gun cable is interrupted
Check/replace gun cable
Cascade in gun is
interrupted --> defective
Check/replace gun
E13
Coil current too big
Cascade of the connected
gun is defective
Check/replace gun
E14
Tribo current too high
The Tribo current has
exceeded the upper limit
value of 12 μA
ATEX guidelines do not
permit higher values.
Reduce Tribo air
Reduce powder quantity
Содержание EPG-Sprint X
Страница 2: ......
Страница 83: ...83 EPG SPRINT X OPERATING MANUAL VERSION 06 2014 ORDER NUMBER DOC2329371 14 4 EC TYPE EXAMINATION CERTIFICATE ...
Страница 100: ...100 EPG SPRINT X OPERATING MANUAL VERSION 06 2014 ORDER NUMBER DOC2329371 ...
Страница 101: ...101 EPG SPRINT X OPERATING MANUAL VERSION 06 2014 ORDER NUMBER DOC2329371 ...
Страница 103: ......
Страница 104: ...CERTI F I E D Order No 2329371 Germany Phone Fax E mail Switzerland Phone Fax E mail ...