Parameter
Value
Description
C26
Manual gun with external
control operating mode
OFF
(Factory setting)
Standard function. The device
automatically recognizes the manual
or automatic gun. The properties of the
corresponding manual or automatic
gun operating mode is described in the
chapter on "Commissioning" and in the
service manuals.
1
Operation always with manual gun. The
remote interface is not used for controlling
the vibrator, instead the remote interface
provides the device with a release and
the OFF-ON command for cleaning
(continuous purging). The remote interface
is described in the service manuals.
2
Same as described for value 1, but the
purge button at the operating front is
without function (disabled).
C31-C40 Password protection
Password-protected; only for Wagner
personnel or appropriately trained persons.
C41-C99 Password protection
Password-protected; only for Wagner
production sites or the Wagner Service
Center with appropriate test equipment.