95
EPG-SPRINT X
OPERATING MANUAL
VERSION 06/2014
ORDER NUMBER DOC2329371
From software version 2.10, two additional parameters are available for special operation
with fi eld controllers.
Parameter
Value
Description
C27
Open-circuit voltage limited
to a maximum of 40 kV
OFF
(Default)
Normal operation with gun
ON
Special application if a fi eld controller is
connected to this control unit.
The open-circuit voltage cannot exceed a
value of 40 kV.
C28
High-voltage module:
Automatic spray current
reset
OFF
This setting must be selected if a fi eld
controller is used in the system as a whole.
It makes no diff erence whether a gun or a
fi eld controller is connected to this control
unit.
ON
(Default)
This setting must be selected if a fi eld
controller is not used in the system as a
whole.