73
EPG-SPRINT X
OPERATING MANUAL
VERSION 06/2014
ORDER NUMBER DOC2329371
Warning No.
Warning
Cause
Remedy
E01
Atomizing air too low
Set point cannot be reached
Causes:
Hose kinked / blocked
Check hoses and hose laying
Input air pressure too low
Ensure that input pressure is
greater than 6 bar
System cannot reach target
setting
Check gun and nozzle
system
E02
Dosing air too low
Set point cannot be reached
Causes:
Hose kinked / blocked
Check hoses and hose laying
Input air pressure too low
Ensure that input pressure is
greater than 6 bar
Injector is not connected
Connect injector correctly
System cannot reach target
setting
Check hoses and hose laying
E03
Feed air too low
Set point cannot be reached
Causes:
Hose kinked / blocked
Check hoses and hose laying
Input air pressure too low
Ensure that input pressure is
greater than 6 bar
Injector is not connected
Connect injector correctly
System cannot reach target
setting
Select smaller set point
value
Example: Feed air for ED
pump max. 3.5 Nm³/h
E04
Fallen below Tribo
current limit for 10 s
The Tribo current set in the
confi guration cannot be reached
Causes:
Tribo air set too low
Increase Tribo air
Powder not fl owing due to
incorrect settings for feed air
and total air
Correct feed air and total air
settings
No powder in tank
Fill powder tank
The powder does not have
the required charging
characteristics
Use suitable powder
Содержание EPG-Sprint X
Страница 2: ......
Страница 83: ...83 EPG SPRINT X OPERATING MANUAL VERSION 06 2014 ORDER NUMBER DOC2329371 14 4 EC TYPE EXAMINATION CERTIFICATE ...
Страница 100: ...100 EPG SPRINT X OPERATING MANUAL VERSION 06 2014 ORDER NUMBER DOC2329371 ...
Страница 101: ...101 EPG SPRINT X OPERATING MANUAL VERSION 06 2014 ORDER NUMBER DOC2329371 ...
Страница 103: ......
Страница 104: ...CERTI F I E D Order No 2329371 Germany Phone Fax E mail Switzerland Phone Fax E mail ...