Fault number
Fault
Cause
Remedy
E15-E17
High-voltage
generator error
Hardware defect
If problem persists, contact
Wagner Service Team
Switch off unit and after
10 seconds, switch on again
E18
Result of corona
measurement is
implausible
Hardware defect
If problem persists, contact
Wagner Service Team
E20
Password error
The password for enabling
the device is not set or has
been lost
Inform Wagner service
center
E21-E25
Exception error
Hardware defect has
occurred
If problem persists, contact
Wagner Service Team
E31
Gun switch
monitoring in
automatic mode
The gun switch line has
been interrupted
Check gun cable
Gun unplugged during
operation
Check gun
E41
No fl ow of atomizing
air
No air is fl owing out of the
control unit
Causes:
Check:
Hose kinked / blocked
The hose laying
Gun blocked
The air supply to the
control unit
Input pressure > 6 bar
Compressed air switched
off
Open compressed air
E42
No fl ow of dosing air
No air is fl owing out of the
control unit
Causes:
Check:
Hose kinked / blocked
The hose laying
The air supply to the
control unit
Input pressure > 6 bar
Injector is not connected
Connect injector
Compressed air switched
off
Open compressed air
Содержание EPG-Sprint X
Страница 2: ......
Страница 83: ...83 EPG SPRINT X OPERATING MANUAL VERSION 06 2014 ORDER NUMBER DOC2329371 14 4 EC TYPE EXAMINATION CERTIFICATE ...
Страница 100: ...100 EPG SPRINT X OPERATING MANUAL VERSION 06 2014 ORDER NUMBER DOC2329371 ...
Страница 101: ...101 EPG SPRINT X OPERATING MANUAL VERSION 06 2014 ORDER NUMBER DOC2329371 ...
Страница 103: ......
Страница 104: ...CERTI F I E D Order No 2329371 Germany Phone Fax E mail Switzerland Phone Fax E mail ...