57
EPG-SPRINT X
EPG
SPRINT X
0
%
100
%
10
20
30
40
50
60
70
80
90
Ø
12
10
11
9
8
m /h
2.0
3.0
0.5
0.3
0.1
1.5
3
5.5
4.5
3.5
2.5
Tri
P_01769
19
24
36
37
33
OPERATING MANUAL
VERSION 06/2014
ORDER NUMBER DOC2329371
7.9
STARTING OUTPUT SETTING (ZERO ADJUSTMENT)
Procedure: (if no powder is fed at 0%)
1.
Press "Powder Quantity" button 36 for around 2 seconds. The "Powder Quantity"
LED 37 fl ashes rapidly, the powder quantity display 33 fl ashes. The current value is
shown in the LED display 19 (e.g., 1.00 means a factory setting of 0.00 Nm³/h).
2.
Turn rotary controller 24 until just a small amount of powder is fed.
3.
To save, hold down the “Powder Quantity” button 36, LED display 19 fl ashes.
To discard the set value, press any button briefl y.
The value that was originally set is reloaded.
Note:
The starting output value is set to 0.00 at the factory.
If the set value is changed, the coating parameters also change, as altering the value alters
the feed air (see diagram).
This function can be used to set the point from which powder is fed.
The starting output setting is subject to:
The diameter of the powder hose
The length of the powder hose
The feed properties of the powder
Содержание EPG-Sprint X
Страница 2: ......
Страница 83: ...83 EPG SPRINT X OPERATING MANUAL VERSION 06 2014 ORDER NUMBER DOC2329371 14 4 EC TYPE EXAMINATION CERTIFICATE ...
Страница 100: ...100 EPG SPRINT X OPERATING MANUAL VERSION 06 2014 ORDER NUMBER DOC2329371 ...
Страница 101: ...101 EPG SPRINT X OPERATING MANUAL VERSION 06 2014 ORDER NUMBER DOC2329371 ...
Страница 103: ......
Страница 104: ...CERTI F I E D Order No 2329371 Germany Phone Fax E mail Switzerland Phone Fax E mail ...