EPG-SPRINT X
OPERATING MANUAL
VERSION 06/2014
ORDER NUMBER DOC2329371
Properties of the characteristic curve
Field of application/remarks
Standard level (black)
for poorly rechargeable types of powder
Open-circuit voltage 100 kV
for high powder application
Maximum current 120 μA
for high application eff ectiveness
(Current limitation at 120 μA)
This setting corresponds to the usual
Wagner high-voltage modules and
control units.
Medium level (gray)
for small surfaces
Open-circuit voltage 100 kV
for types of powder that recharge well
Maximum current 120 μA
for metallic powder
to reduce the eff ects of overcoating such
as craters and orange peel
Increasing the open-circuit voltage
allows for a greater distance between
the spray gun and the work piece while
maintaining suffi
cient powder charging.
Soft level (white)
for types of powder that recharge well
Open-circuit voltage 100 kV
for small powder application
Maximum current 80 μA
for post-coatings