Periodic Maintenance Schedule—Gas Burners
Task
Interval*
(hours of service)
Daily
6 Months
Yearly
---
(1000)
(1200)
Check fuel level.
Clean the machine.
Inspect electrical components.
Inspect the blower motor and belt.
Replace the belt if necessary.
Inspect the heat exchangers.
Inspect and test the burner.
As needed or upon changing job sites;
see chapter
Burner Setup
.
■
Adjust the ionization probe and electrode.
Replace the electrode if necessary.
■
Check the burner orifice.
■
Check the air damper setting.
■
Check the gas pressure.
*