4.9
Power Requirements for Third-Party Generators
NOTICE:
Machine damage may occur if an undersized generator (genset) is used
to power the machine. The starting kVA of the generator must be at least 33 kVA at
a maximum voltage dip of 20%.
4.10
Connecting Power to the Machine
Note: On machines equipped with generators, the power connections were made
at the factory. No further electric power connections are necessary.
Requirements
■
230V 60 Hz and 115V 60 Hz power sources
■
Machine properly positioned
Procedure
Perform the procedure below to connect power to the machine.
1. Open the access doors
(a)
.
2. Connect the 120V plug
(b)
to a 120V source.
3. Connect the 230V plug
(c)
to a 230V source.
4. Close the access doors and run the extension cords out the access hole
(d)
.
WARNING
Fire hazard and electric shock hazard. The use of undersized extension cords can
lead to fire and electric shock. Fire and electric shock can cause severe injury.
►
Do not use undersized extension cords.
c
b
wc_gr008343
d
a