
ghi_tx001258gb_FM10.fm
60
Operation
HI750
4.26
Operating States of the Beckett Burner Controller
Burner states
The burner control has several states that it sequences through during normal
operation. These operating states are described below.
.
WARNING
Fire, explosion, asphyxiation, and burn hazards.
►
Refer to the burner manufacturer’s documentation for safe operating
procedures.
wc_gr007665
Yellow
pump prime
Green
flame / recycle
Red
reset button / lockout
Standby
Run
Ignition
carryover
State
10
30
Operating
wc_gr007662
State
Action or Function
Standby
As soon as power is supplied to the burner control, the burner control
enters the standby state until there is a call for heat, or power is
disconnected.
Valve-on-
delay
(pre-time)
When the setpoint of the temperature controller is set to a temperature
higher than that of the heat transfer fluid, the output contacts of the
temperature controller close, completing a circuit between the two
terminals labeled “T” of the burner control. This is the call for heat. The
burner control enters the valve-on-delay state.
The valve-on-delay state lasts 15 seconds. During this state:
■
Power is sent to the burner motor.
■
Power is sent to the electrodes.
■
If the cad cell detects flame anytime during the valve-on-delay state,
the burner control goes into the lockout state.
Содержание 5000620856
Страница 6: ...ghi_tx001257gb_FM10 fm 6 Foreword HI750 ...
Страница 27: ...HI750 Labels ghi_si000380gb_FM10 fm 27 BB CC FF ...
Страница 115: ...wc_tx003699gb_FM10 fm 115 Kubota Genset Genset Maintenance ...
Страница 122: ...ghi_td000360gb_FM10 fm 122 Technical Data HI750 Notes ...
Страница 135: ...HI750 Schematics ghi_tx001261gb_FM10 fm 135 13 Schematics This page is intentionally left blank ...
Страница 142: ......
Страница 143: ......