wc_tx001396gb_FM10.fm
86
Burner Setup—Gas
HI750
8.6
Checking the Burner Air Damper Setting
Requirements
■
Machine shut down
■
Burner cool
Procedure
Perform the procedure below to check the air damper setting.
Note: This procedure must be performed at each new job site. The proper setting
depends on environmental conditions at the job site.
1. Shut down the machine and allow it to cool.
2. Remove the burner cover.
3. Loosen the two screws
(a)
that secure the air adjustment plate
(b)
.
4. Rotate the air adjustment plate so that the proper number on the air adjustment
plate lines up with the setting indicator
(c)
. See topic
Factory Settings
.
5. Once the air adjustment plate is set, tighten the two screws
(a)
.
Result
The air damper setting has now been checked.
wcghi_gr005205
b
a
c