COOKING CONTROLS
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
CAUTION
Certain components in this system are
subject to damage by electrostatic discharge during
field repairs. A field service ground kit is available to
prevent damage. The field service grounding kit must
be used any time the control board is handled.
1.
Remove control panel as outlined under
COVERS AND PANELS.
2.
To remove:
A.
Solid State Control: Proceed to Step 3.
B.
Computer Control: Remove mounting nuts
securing computer control and mounting
panel to front control panel. Proceed to Step
4.
Fig. 9
3.
Remove mounting nuts securing solid state
control to mounting panel.
Fig. 10
4.
Lift the control – with mounting panel attached –
off the front control panel.
5.
Reverse procedure to install, and check for
proper operation.
NOTE:
If a replacement control was installed,
program the control with the customer's settings and
products.
DISCARD VALVE SWITCH
(KLEENSCREEN FRYERS ONLY)
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
1.
Open the fryer section doors above filter pan.
2.
Pull out filter drawer, remove filter tank assembly,
and push the tank support arms back into place
under the fryer.
3.
Remove bottom cover from base frame.
Fig. 11
GR Series Gas Fryers with NCC Controls (formerly Tridelta / Built after 3/05) - REMOVAL AND REPLACEMENT
OF PARTS
Page 11 of
56
F35660