6.
Remove screws securing probe mounting clips
and probe to the fryer heat tube (inside tank),
then remove probe.
Fig. 23
7.
Reverse procedure to install.
8.
Check cooking controls calibration as outlined in
COOKING CONTROL CALIBRATION.
HIGH LIMIT THERMOSTAT
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas
before servicing the unit and follow
lockout / tagout procedures.
CAUTION
Do not sharply bend and kink the
temperature probe, or damage may occur.
1.
Drain shortening from fryer tank.
2.
Remove burners as outlined under GAS
BURNERS.
3.
Disconnect lead wires from high limit thermostat.
4.
Remove screws securing the high limit to
mounting bracket.
Fig. 24
5.
Remove the capillary tube retaining and packing
nuts.
Fig. 25
6.
Remove screws securing mounting clips and
capillary tube to the fryer heat tube (inside tank),
then remove capillary tube.
GR Series Gas Fryers with NCC Controls (formerly Tridelta / Built after 3/05) - REMOVAL AND REPLACEMENT
OF PARTS