A.
Remove gas line fittings from gas
combination valve, and install (in same
orientation) on the replacement valve.
Fig. 17
6.
Reverse procedure to install, and check for
proper operations.
NOTE:
Clean the pipe threads, and apply pipe joint
compound to threads. Any pipe joint compound used
must be resistant to the action of propane gases.
GAS PILOT
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas
before servicing the unit and follow
lockout / tagout procedures.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
1.
Remove pilot burner assembly and bracket from
pilot bracket stand-off on the fry tank.
Fig. 18
2.
Remove wire tie, and disconnect ignitor cable
from ignitor/flame sense electrode on the gas
pilot.
Fig. 19
NOTE:
When installing, replace wire tie to secure
ignitor cable.
3.
Disconnect pilot tube from gas pilot.
4.
Remove two screws securing gas pilot to
mounting bracket.
A.
To remove gas orifice from pilot for
inspection or cleaning, disconnect the gas
orifice fitting from pilot body.