Fig. 15
5.
Reverse procedure to install.
GAS ORIFICE
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas
before servicing the unit and follow
lockout / tagout procedures.
1.
Remove gas orifice spud from orifice extension.
NOTE:
The spud screws into the orifice extension.
When installing, do not overtighten the spud, or
damage to the threads may occur.
Fig. 16
2.
Reverse procedure to install.
GAS COMBINATION VALVE
Disconnect the
electrical power to the machine and
follow lockout / tagout procedures.
Shut off the gas
before servicing the unit and follow
lockout / tagout procedures.
All gas joints disturbed during
servicing must be checked for leaks. Check with a
soap and water solution (bubbles). Do not use an open
flame.
NOTE:
If a gas combination valve is malfunctioning,
do not attempt to disassemble the valve for repair.
Install a replacement gas combination valve.
1.
Remove burners as outlined in GAS
BURNERS.
2.
Disconnect lead wires from gas combination
valve.
3.
On fryers with gas valve arm extension only,
remove cotter pin securing handle to gas valve
on/off knob adaptor, and pull handle away from
valve assembly.
4.
Disconnect pilot tube from has combination
valve.
5.
Disconnect gas line fittings, then remove gas
combination valve.
GR Series Gas Fryers with NCC Controls (formerly Tridelta / Built after 3/05) - REMOVAL AND REPLACEMENT
OF PARTS
Page 13 of
56
F35660
Rev. A (0717)