![Vonsch Quatrofrem Series Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/vonsch/quatrofrem-series/quatrofrem-series_configuration-and-diagnostics_1049784081.webp)
UNIFREM v.3.41x
10 May 2017
Page 81 from 180
SPECIAL SETTING R1
Group of parameters number [221]
Special function setting for relay 1. R1 Source [697] (page 80) must be chosen as "Special".
MENU \ SETTINGS \ INPUTS AND OUTPUTS \ RELAY OUTPUTS \ RELAY 1 \ SPECIAL SETTING R1
Name [ID]
Description
Def.
R1 Signal [189]
Signal that is evaluated for the relay switch. Either numeric or discrete
signal can be chosen.
[76]
Converter
state
Signal
R1
switch-on
[301]
Conditions for R1 switch-on.
Run
Look choises of parameter's Converter state [76] (page 23)
R1
switch-off
[309]
Conditions for R1 switch-off.
Look choises of parameter's Converter state [76] (page 23)
Relay 2
Group of parameters number [187]
Relay 2 setting. Relay is connected to the terminals: NC - X2:28, COM - X2:29, NO - X2:30 (NC - X2:21,
COM - X2:22, NO - X2:23 for UNIFREM 400 M).
MENU \ SETTINGS \ INPUTS AND OUTPUTS \ RELAY OUTPUTS \ RELAY 2
Name [ID]
Description
Def.
R2
Source
[698]
Relay switching function setting. Functionality is the same as RELAY 1 R1 Source
[697] (page 80).
Fault
Look choises of parameter's R1 Source [697] (page 80)
R2 switch-on
time [316]
Relay switch-on time delay.
0,00
s
0,00
s
÷
3600,00 s
After establishment of the switch condition, the relay will switch-on after a selected amount
of time.
R2 switch-off
time [317]
Relay switch-off time delay.
0,00
s
0,00
s
÷
3600,00 s
If the switch condition is no longer valid, the relay remains switched on for a selected
amount of time.
R2 Logic [756]
Determines the relay output evaluation mode. The condition will be evaluated first,
then the switch times will be evaluated and the relay logic will be evaluated last.
Direct
Direct
If the switch conditions are met, the relay will switch on.
Inverted
If the switch conditions are met, the relay will switch off.
SPECIAL SETTING R2
Group of parameters number [223]
Special function setting for relay 2. R2 Source [698] (page 81) must be chosen as "Special".
MENU \ SETTINGS \ INPUTS AND OUTPUTS \ RELAY OUTPUTS \ RELAY 2 \ SPECIAL SETTING R2
Name [ID]
Description
Def.
R2 Signal [311]
Signal that is evaluated for the relay switch. Either numeric or discrete
signal can be chosen.
[76]
Converter
state
Signal
R2
switch-on
[313]
Conditions for R2 switch-on.
Fault
Look choises of parameter's Converter state [76] (page 23)
R2
switch-off
[314]
Conditions for R2 switch-off.
Look choises of parameter's Converter state [76] (page 23)